BNI EIP-508-105-Z067
Network interface
3
Configuration via Explicit Messages (continued)
3.5
IO-Link device parameterization
There are two ways to parameterize an IO-Link device
connected to the IO-Link Port.
–
Parameterization via the web server (see I/O ports on
page 36)
–
Parameterization via Explicit Messages
The following section describes, for example, how via
Rockwell RSLogix 5000 an IO-Link device can be
parameterized via Explicit Messages.
The MSG modules are used in the PLC program (see
Fig. 3-2).
Fig. 3-2:
MSG modules
3.5.1
Read IO-Link parameters
Service code
Class
0x32
0x96
n: Number of ports
1)
Tab. 3-6:
Values for read IO-Link parameters
Source Length must at least correspond to the read
parameters, but can also be bigger (in this example
100 bytes).
1. As a Source Element (Write) and as a Destination
Element (Read), create a SINT[100] Array and select
the first row [0].
Fig. 3-3:
Create SINT[100] Arrays
14
english
Instance Attribute
1...n
0x03
1)
(Read
parameters)