WebUI/web interface (continued)
Parameter (IODD)
The Parameter (ISDU) tab page is only displayed if
a suitable IODD is uploaded for the IO-Link device
connected to the selected port. u
g
i
.
eneral
nfOrMatiOn
Under p
(iOdd), the device identification data of
araMeter
the IO-Link device is displayed in a table when the
i
tab page is selected (e.g. Fig. 6-20). The
dentificatiOn
corresponding texts are saved in the IODD.
The input values can either be read out from the IO-Link
device individually for a subindex by clicking on r
the entire tab page via r
ead all
indicated by a green bar on the right-hand edge of the
relevant table row.
Fig. 6-20: Dialog view after clicking on r
on r
ead
The a
S
t
is an application-specific field
pplicatiOn
pecific
ag
in IO-Link devices and, in the current example (see
Fig. 6-21), can either be read out from the IO-Link device
with r
or can be individually configured by clicking on
ead
the gray input field with the same name and described with
(provided the required write authorization exists). It is
w
rite
also possible to enter a company-internal device name in
this field.
Fig. 6-21: Application Specific Tag
If the IODD of the IO-Link device at the currently selected
port also has parameters, these are also displayed in the
form of a table (see Fig. 6-22). Similarly to the process for
device identification data, parameter values and associated
texts from the saved IODD can be configured, depending
on the parameter, via r
or r
ead
If available, click on the
icon to open a dropdown list
and select a value or select a value within a specific range
and confirm with w
.
rite
If there is no r
button next to subindices, these indices
ead
cannot be processed individually, but only as a complete
index.
www.balluff.com
iOdd, see
plOad
or for
ead
. A successful request is
or, for each subindex,
ead all
.
ead all
Fig. 6-22: p
dialog: Extract from the parameter list of an IO-Link
OrtS
device with uploaded IODD after clicking on r
Read for individual subindices
Each changed value must be written individually
by clicking on w
!
rite
ISDU Parameter
Configuration parameters of the IO-Link device can be
read and written via the iSdu p
parameter indices and subindices of the IO-Link device
follow the IO-Link conventions and are described in the
corresponding user's guide.
Parameter indices and subindices can be entered both in
decimal and hexadecimal format, while data can only be
entered in hexadecimal format.
An input is confirmed with S
et
d
.
elete
Events
Under e
, you can see whether there is a diagnosis
ventS
event from the IO-Link device.
The events can be displayed in ascending or descending
order. The list of events can be updated via further options
of the e
card (see Fig. 6-23) or can be downloaded in
ventS
CSV format.
Fig. 6-23: Further options of the e
ventS
or
ead all
option. The
araMeter
or can be rejected with
tab page
english
31