Network interface
5

Display

5.1
General
With the installed display the address is displayed directly
on the devices.
The following address types are possible:
IP address
Subnet mask
Gateway address
Each address consists of 4 octets.
The display also shows information about the update of
the hardware and firmware.
The display has a lock function which can be activated
from the system control. Editing is no longer possible if the
lock is set.
5.2

Address details

IP address:
192.168.1.1
Subnet mask:
255.255.255.0
Gateway address: 192.168.1.1
5.3

Control and display

1
Display
2
Arrow button
3
Octet cursor
Fig. 5-1:
Explanation of the control panel
5.4

Display information

Cursor to select the address type
IP
SN
GW
3
IP:
IP address
SN:
Subnet address
GW:
Gateway address
Fig. 5-2:
Explanation of display
20
english
4
Address type cursor
5
Set button
6
LEDs
2
1
0
Cursor to select the octet
3
First octet
2
Second octet
1
Third octet
0
Fourth octet
5.5

Design and symbols

In the following diagrams, a number of symbols are used
to describe the display functionality:
Symbol
Meaning
Current state
Switch
Press the Set button briefly
Press the Set button for several seconds
(≥ 3 s)
Press the arrow button briefly
Tab. 5-1:
Explanation of symbols
5.6

Startup

BALLUFF
Module name
Hardware and firmware
update
Current IP
Current subnet mask
Current gateway address