WebUI/web interface (continued)
Application recommendation for a Port X in the context of
the other designation variables (see Fig. 6-32):
– name of the device that shows what
d
a
evice
liaS
function the sensor executes (e.g. rear left end switch,
temperature at boiler floor, etc.)
M
p
 4 – selection of the actuation (e.g.
Ode
in
Deactivated, IO-Link [Manual], IO-Link [Autostart] or
Digital In/Out. Depending on the selection, further
dialog fields open, which require an input (e.g. when
the IO-Link [Manual] option is selected).
If no backup and validation are required on the
port, the option IO-Link [Autostart] can be
selected for which the validation and backup are
switched off.
v
– If for the point Mode Pin 4 the
alidatiOn and bacKup
option IO-Link [Manual] has been selected,the following
mandatory fields marked with "*" must be completed.
Selection
Validation
No device
check
V1.0
Compatible
V1.1
Compatible
V1.1
Backup
and
recovery
Check conformity
between
connected
IO-Link device
(1.0) and default
value using
Device and
V1.1
Vendor ID
Recovery
c
t
– if the IO-Link [Manual] or IO-Link
ycle
iMe
[Autostart] options are selected for point Modus Pin 4,
the desired communication cycle can be set by
selecting the corresponding value from the dropdown
list.
M
p
 2 – Is defined as d
Ode
in
www.balluff.com
Backup
Automatic backup
of parameter
values. Changes to
the current
parameter values
are saved.
The parameter
values are restored
when a similar
IO-Link device is
connected.
No automatic
backup of
parameter values.
Changes to the
current parameter
values are not
saved.
The parameter
values are restored
when a similar
IO-Link device is
connected.
/
.
igital in
Out
Fig. 6-32: M
p
 4 selection options dialog and Port 2:
OduS
in
Configuration dialog of the iO-l
The port configuration is not permanently stored.
After a reset, reboot or a deenergized phase, the
settings are lost.
It is not possible to reconfigure a port configured
as an IO-Link directly to another IO-Link mode.
The respective port must be deactivated
beforehand.
It is also not possible to change the validation
information for IO-Link [Manual] without first
deactivating the port.
[M
] option
inK
anual
english