BNI EIP-508-105-Z067
Network interface
3
Configuration via Explicit Messages (continued)
3.2
Example with Rockwell components
1756-L6xS
Stratix 8000
Managed Switch
Fig. 3-1:
System components (example)
Please note the following:
–
Direct connection between PLC and QuickConnect
slave with crossover cable
–
Connection from slave to slave with patch cable
–
For the topology structure only the linear topology with
maximum 20 modules is permitted on the tool side.
–
If required, only one Managed Switch may be used
between PLC and Ethernet/IP slave.
–
An Electrical Lock Signal is required for triggering the
QuickConnect sequence, which reads the supply
voltage of the QuickConnect slaves via the control.
3.3
PLC program
Information about the PLC program and Add
Application Logic, see Allen Bradley Ethernet/IP
QuickConnect Application Technique.
12
english
1756-EN2T
Electrical
Lock Signal
I/O Modules
Power
Supply
QuickConnect Armor-
Block I/O Modules
Tool Changer