Herunterladen Inhalt Inhalt Diese Seite drucken

Process Data Info And Configuration - Balluff Bos R254K-Uui-Re10-S4 Konfiguration

Io-link-konfiguration
Vorschau ausblenden Andere Handbücher für BOS R254K-UUI-RE10-S4:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

BOS R254K-UUI-RE10-S4
Photoelectric Sensors
6
System Functions (continued)
6.7

Process Data Info and Configuration

6.7.1
Description
Process data information and configuration offers various
possibilities related to process data:
Selection of a process dataset specified by the device
Information about the structure of the input and output
data
Information about the last valid value for input and
output data
As a diagnosis function, monitoring of the updates of
certain process values is available. If these are not updated
in the specified time, the device sends corresponding
diagnosis messages.
Invalid Process Data
Input data (from the device to the master) is only marked
as invalid if the device has the Failure device status.
In the case of individual pieces of faulty data, the
data is not marked as invalid but is instead
replaced by substitution values or error codes.
This is to be taken into account during the
evaluation.
Invalid output data (from the master to the device) is not
processed by the device. The device then operates only
with the last valid data.
6.7.2
ISDU
Name
Index
Process Data
0x0051 (81)
Profile
selection
Process Data
0x000E (14)
Input
Descriptor
Process Data
0x000F (15)
Output
Descriptor
Last Valid
0x0028 (40)
Process Data
Inputs
Last Valid
0x0029 (41)
Process Data
Outputs
Tab. 6-24: Process data info and configuration – ISDU
www.balluff.com
Sub index
Access
0
R/W
0
R
0
R
0
R
0
R
Length
Data Type
1 Byte
ENUM
= PD input
UINT8[]
data length
= PD output
UINT8[]
data length
Variant 1: 1
Special
Variant 2: 2
Variant 3: 17
Variant 4: 6
1
Special
Data
Default
Storage
Yes
1
english
95
Inhaltsverzeichnis
loading