BOS R254K-UUI-RE10-S4
Photoelectric Sensors
5
Secondary Device Functions (continued)
5.11
Internal Temperature
5.11.1 Description
The sensor is equipped with internal temperature
monitoring. This records the device temperature as well as
the maximum and minimum values during production and
since the last time the sensor was restarted.
An upper and a lower threshold value can be defined for
the device temperature module. If the threshold is
exceeded or if device limit values are exceeded or
undercut, the senor triggers IO-Link events.
5.11.2 Process Data
Object ID
Name
0x0050 (80)
Device Temperature
Tab. 5-52: Internal temperature – Process data
5.11.3 ISDU
Name
Index
Device Temperature
0x0052 (82)
Device Temperature
Minimum Device
Temperature Since
Reset
Maximum Device
Temperature Since
Reset
Lifetime Minimum
Device Temperature
Lifetime Maximum
Device Temperature
Device Temperature
0x0053 (83)
Alarm Configuration
Lower Alarm Level
Device Temperature
Upper Alarm Level
Device Temperature
Tab. 5-53: Internal temperature – ISDU (overview)
www.balluff.com
Description
Current device temperature in °C.
Sub index
Access
Length
0
R
10 Byte
1
R
2 Byte
2
R
2 Byte
3
R
2 Byte
4
R
2 Byte
5
R
2 Byte
0
R/W
4 Byte
1
R/W
2 Byte
2
R/W
2 Byte
Data Type
Data Storage
INT16[]
Yes
INT16
No
INT16
No
INT16
No
INT16
No
INT16
No
INT16[]
Yes
INT16
No
INT16
No
english
Direction
Output
Default
–
–
–
–
–
–
–
0x0055 (85)
0xFFF6 (−10)
73