Description
With the Ping function, an IO-Link device can be found
again by starting signaling on the LED of the device by
means of a system command.
4.2.2
ISDU
Name
Index
Ping Timeout
0x00FE (254)
Tab. 4-2:
Device detection – ISDU
Ping Timeout
The Ping Timeout parameter sets the duration of the ping
signal that is displayed via LEDs.
The value is specified minutes. The value range from 0 to
30 minutes is allowed. If the parameter is set to 0, the ping
signal is deactivated. The parameter is reset by Application
Reset and Factory Reset (also see section Reset
Commands on page 87).
4.2.3
System Commands
Command Value
Device Action
0xAF (175)
Start Ping
Tab. 4-3:
Device detection – System Commands
www.balluff.com
Sub index
Access
0
R/W
Length
Data Type
2 Byte
INT
Data
Default
Storage
Yes
1
english