Herunterladen Inhalt Inhalt Diese Seite drucken

Voltage And Current Monitoring - Balluff Bos R254K-Uui-Re10-S4 Konfiguration

Io-link-konfiguration
Vorschau ausblenden Andere Handbücher für BOS R254K-UUI-RE10-S4:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

BOS R254K-UUI-RE10-S4
Photoelectric Sensors
5
Secondary Device Functions (continued)
5.9

Voltage and Current Monitoring

5.9.1
Description
The voltage and current module sends messages about
over-current, short-circuit, wire breakage, over-voltage and
under-voltage. Over-voltage and under-voltage detection
starts a timer. If the voltage level does not return to the
normal operating voltage threshold before the timer
expires, the module sends the messages.
The messages include device status, IO-Link events,
process data and LED signaling.
5.9.2
Mathematics/Algorithm
In SIO-operation, the threshold for under-voltage is 10 V
and is 30 V for over-voltage.
If the device is in IO-Link operation, the under-voltage state
occurs at 18 V and at 30 V for over-voltage.
5.9.3
Process Data
Object ID
Name
0x0016 (22)
Overload / short-circuit
pin 2
0x0017 (23)
Undervoltage
0x0018 (24)
Overvoltage
0x001A (26)
Cable break pin 2
0x0044 (68)
Overload pin 2
Tab. 5-43: Voltage and current monitoring – Process data
Also see section Process Data Profiles on page 9.
5.9.4
ISDU
Name
Index
Voltage
0x2200
Monitoring
(8704)
Detection
Time
Duration
Tab. 5-44: Voltage and current monitoring – ISDU
Voltage Monitoring Detection Time Duration
This parameter is used to define how long the under-
voltage or over-voltage must be present before it is
displayed. The unit is given in milliseconds. The values
must be in the range between 10 and 1000, in increments
of 5 milliseconds. The default value is 10 milliseconds.
www.balluff.com
Description
TRUE = overload or short-circuit detected at pin 2.
TRUE = the voltage level is below the threshold value.
TRUE = the voltage level is above the threshold value.
TRUE = cable break detected at pin 2.
TRUE = overload detected at pin 2.
Sub index
Access
0
R/W
Length
Data Type
2 bytes
UINT16
Direction
Input
Input
Input
Input
Input
Data
Default
Storage
Yes
10
english
69
Inhaltsverzeichnis
loading