Secondary Device Functions (continued)
The maximum number of storage cycles is
500,000 and, with a switch-on and switch-off
every 12 minutes (with static counter), this means
a service life of over 10 years.
If switched on and off more frequently or in the
case of dynamic storage, the maximum storage
time is reduced depending on the application.
Current Operating Hours
This parameter saves the value of the operating hours
since the last commissioning in seconds.
Total Operating Hours
This parameter saves the value of the operating hours
since the first commissioning in seconds.
Custom Operating Hours
This parameter saves the value of the operating hours
since the last reset in seconds.
Operating Hours Saving Mode
The current storage behavior can be set.
Value
Meaning
Description
0x00 (0)
Dynamic
The first save operation is
performed 1 minute after
switching on; the storage
interval than doubles after
every save operation. This is
limited to a storage interval
of 12 minutes. The intervals
are 1, 2, 4, 8, 12 minutes.
0x01 (1)
Static
Operating hours counters
are stored every 12 minutes.
Tab. 5-38: Operating hours counter – Operating hours saving mode
www.balluff.com
5.7.5
System Commands
Command Value
Device Action
0x81 (129)
Application Reset – Resets
Custom operating hours to the
default value.
0x82 (130)
Reset Factory Settings – Resets
Custom operating hours and
Operating hours saving mode to
the default value.
0xA5 (165)
Maintenance Reset – Resets
Custom operating hours to the
default value.
Tab. 5-39: Operating hours counter – System Commands
For an overview of all System Commands, see section 3.5
on page 21.