Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BOS R254K-UUI-RE10-S4 Konfiguration Seite 155

Io-link-konfiguration
Vorschau ausblenden Andere Handbücher für BOS R254K-UUI-RE10-S4:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

BOS R254K-UUI-RE10-S4
Photoelectric Sensors
5
Secondary Device Functions (continued)
Speed Monitoring Value
With Speed Monitoring Value, the current speed value can
be read.
5.3.5
System Commands
Command
Device Action
Value
0x81 (129)
Application Reset – Resets writable
parameters to the default value.
0x82 (130)
Reset Factory Settings – Resets writable
parameters to the default value.
0xAA (170)
Signal Speed Monitoring Reset – Resets
the speed value and flags.
Tab. 5-15: Speed Monitoring State – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
5.3.6
Events
Event Code
Event Type
0x8D08 (36104)
Warning
0x8D09 (36105)
Warning
Tab. 5-16: Speed Monitoring State – Events
5.3.7
Variant Dependence
The functionality is available in all variants.
www.balluff.com
Description
Speed value is below the limit.
Speed value is above the limit.
Device Status
0 – Device is operating properly.
0 – Device is operating properly.
english
51
Inhaltsverzeichnis
loading

Inhaltsverzeichnis