7.3.1 Switch the residual current device and the
circuit breaker back on again
> 15 mm
Fig. 19: Switch the residual current device and the
circuit breaker back on again
u Press the multi-function button up to the end
position (> 15 mm).
ð Residual current device and miniature circuit
breaker are switched on again.

7.3.2 Check the residual current device

90°
8 ... 10 mm
> 5 mm
~2 s
Fig. 20: Check the residual current device
u Insert a flat screwdriver with a blade width of 8
to 10 mm into the slot of the multi-function but-
ton.
*click*
*click*
u Turn the multi-function button 90° in the anti-
clockwise direction.
u Press the multi-function button for about two
seconds (> 5mm).
ð If the residual current device is functional, the
residual current device trips and the "Fault"
symbol lights up on the LED information panel.
u Switch the residual current device on again.
1 "7.3.1 Residual current device and circuit
breaker reactivated." [} 39]
7.4

User web interface

The following settings can be made via the user
web interface:
n Select charging mode (solar charging)
n Export charging statistics
n Select time server (NTP)
n Change network settings (e. g. IP address)
n Manage RFID cards in local whitelist
n Change password to web interface

7.4.1 Calling up the user web interface

Requirement:
ü During commissioning, the qualified electrician
has connected the product to the same network
your terminal device is connected to (e. g.
smartphone, tablet, laptop).
u Open web browser on terminal device (e. g.
smartphone, tablet, laptop).
The user web interface can be reached via
http://IP address.
Example:
n IP address: 192.168.0.70
n The user web interface can be reached via:
http://192.168.0.70
IP address is not known
If the IP address is not known, the web interface
can be reached via the type / serial number. It is in-
dicated on the name plate of your product as fol-
lows: Type number.Serial number
EN
39