Energy meter measures external consumers and
charging stations (total consumption)
LP1
DLM Master
Fig. 15: Energy meter measures external consumers
and charging station (total consumption)
Configuration
u Navigate to the menu "Load Management" >
"Dynamic Load Management" and set the fol-
lowing parameters:
Parameter
Setting
Dynamic Load
u Select "DLM Master (With in-
Management -
ternal DLM-Slave)".
DLM Master/
Slave
EVSE Sub-Dis-
Maximum mains current avail-
tribution Limit
able for load management.
(L1/L2/L3) [A]
If only one charging point is in-
tegrated, the value of the para-
meter "Installation Current Limit
[A]" must be entered here.
Switch / router
Fuse F2
Fuse F3
Meter
M2
Main
meter
M1
Main fuse F1
Electrical network
Parameter
Setting
Operator EVSE
Upper current limit for load man-
Sub-Distribu-
agement. This value can be
tion Limit (L1/
changed during operation (e.g.
L2/L3) [A]
temporarily from an EMS).
If only one charging point is in-
tegrated, the value of the para-
meter "Installation Current Limit
[A]" must be entered here.
External Meter
u Select "On".
Support
Meter configur-
Setting for which energy meter
ation (Second)
was used.
IP address of
IP address of the energy meter.
second meter
Port number of
Port number of the energy
Second Meter
meter.
Main Distribu-
Upper current limit for load man-
tion Limit (L1/
agement (rated current of the
L2/L3) [A]
main fuse at the building con-
nection). The external con-
sumers that are recorded by the
energy meter must also be con-
sidered here.
External Meter
This setting specifies how the
Location
external energy meter is con-
nected.
n "Including EVSE Sub-Distribu-
tion": Energy meter measures
external consumers and char-
ging station(s) (total consump-
tion).
n "Excluding EVSE Sub-Distri-
bution": Energy meter meas-
ures external consumers only.