u Click the "Save" button to save the setting(s).
6.9.2 "Standalone with authorisation" operating
mode
The product is operated as a stand-alone solution
without connection to a master backend system.
The authorisation occurs through RFID cards and a
local whitelist.
u Navigate to the menu "Backend" > "Connec-
tion" and set the following parameters:
Parameter
Connection Type
u Click the "Save" button to save the setting(s).
u Navigate to the menu "Authorization" > "Free
Charging" and set the following parameters:
Parameter
Free Charging
If in doubt allow char-
ging
Navigate to the submenu "RFID Whitelists" and set
the following parameters:
Parameter
Enable local whitelist
u Click the "Save" button to save the setting(s).
If connected to a backend system: If the parameter
"Enforce using Secure RFID" (menu "Authoriza-
tion" > "RFID Settings") is activated, only counter-
feit-proof RFID tokens in accordance with VDE-AR-
E 2532-100 will be accepted.
Programming RFID cards
u Navigate to the menu "Whitelists" > "Add entry".
u Hold the RFID card in front of the RFID card
reader to transmit the UID of the RFID. Alternat-
ively, the RFID UID can be entered manually.
u Click the "Add entry" button.
28
Setting
u Select "No Backend".
Setting
u Select "Off".
u Select "Off".
Setting
u Select "On".
A list with all the UIDs of the RFIDs can also be ex-
ported or imported.
6.9.3 "Standalone Backend-System" operating
mode
The product can be connected to a backend sys-
tem via wireless communication or ethernet. The
product is operated via the backend system.
A detailed description of networking, the
connection to a backend system and load
management, including application ex-
amples, can be found on our website in the
download section for the selected product.
A Micro-SIM card is required for connecting
via wireless communication.
u Insert the SIM card.
1 "6.4 "Insert SIM card"" [
u Navigate to the menu "Backend" and set the
following parameters:
Parameter
Setting
Connection
u Select "GSM" or "Ethernet".
Type
OCPP Mode
Communication protocol
If "OCPP Mode" = "OCPP-S 1.5" or "OCPP-S 1.6":
Parameter
Setting
SOAP OCPP
URL address of the backend sys-
URL of
tem
Backend
(Standard
OCPP)
If "OCPP Mode"= "OCPP-J 1.6":
Parameter
Setting
WebSockets
WS / WSS-URL of the OCPP
JSON OCPP
backend system
URL of the
Backend
 24]
}