Behavior in cases of error

Defective operational readiness of the system may be due to a simple error. Check the system for the
listed sources of error.
If the error cannot be removed after an inspection to the named causes, then inform customer service
or your dealer.
Problem: Motor does not start
Possible causes:
No power supply
The main switch (2) is not switched on, or is
defective
Defective fuse
"LIFT" (3) button defective
Motor defective
Problem: Motor starts, load is not lifted
Possible causes:
Load is too heavy
Hydraulic oil illing level is too low
Emergency discharge ixture is not closed
Pressure line leaking
The connector for the left is designed for a
clockwise phase order.
Problem: The lift cannot be lowered
Possible causes:
Lifting table is sitting on an obstacle
Hydraulic valve defective
"LOWER" (4) button defective
Incorrect push button actuated
16
All manuals and user guides at all-guides.com
Remedy:
Check the power supply
Check the main switch (2).
Have fuses checked
Inform customer service
Inform customer service
Remedy:
Unload the lift
Reill hydraulic oil
Check emergency discharge ixture
Inform customer service
Your power socket may not match. One of the
phases must be swapped.
Remedy:
See 7.1 Moving onto an obstacle
Inform customer service
Inform customer service
Push the correct push button