5. Commissioning, operation
If Windows
settings of the system control must be changed to English (USA), since
otherwise, communication problems might occur.

5.6.2.3 Data logger

The data logger is used for recording measured values over a certain time span.
After setting up COM ports, the baud rate and the min./max. address or interval, the
recording can be started. For continuous recording, it is possible to record the measured
data in the selected interval in a text file divided by tabs.
The recording is started with the green start symbol. Stop the recording using the red
stop symbol.
5.6.2.4 Modbus
register and functional description
®
The following documents (available under www.Modbus.org) are recommended for
understanding the Modbus
Modbus APPLICATION PROTOCOL SPECIFICATION
Modbus over Serial Line Specification and Implementation Guide
The register structure is described in the following.
Communication via messages
General form of the messages
Instrument address
8 bit
In accordance with Modbus
intermission of at least 3.5 characters.
WIKA operating instructions, model GDM-RC-100-T
is used with non-Latin character sets (e.g. Chinese), the area
®
architecture which the following chapters will refer to.
®
Function
8 bit
specification, separate messages must be divided by an
®
Data
n x 8 bit
CRC check
16 bit