Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - WIKA GDM-RC-100-T Betriebsanleitung

Hybrid-gasdichtewächter mit referenzkammer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9. Specifications
Switch contacts
Switching direction
EN
Switch point setting
Maximum number of cycles
Insulation resistance of contact > 100 MOhm
Min. switching current
Min. switching voltage
Circuits
Monitoring functions
Self-monitoring
Electrical characteristics
Supply voltage
≤ DC 30 V
≤ DC 50 V
≤ DC 75 V
≤ DC 125 V
≤ DC 250 V
≤ AC 125 V
≤ AC 250 V
1) Only up to 70 °C [158 °F] ambient temperature.
At 70 ... 80 °C [158 ... 176 °F] ambient temperature, the contacts must be operated with a maximum of 1 A.

Electrical connection

Connection type
Wire cross-section
Grounding
36
Falling density
Rising density
In accordance with customer specification, max. difference
of lowest to highest contact: 4 bar
10,000 mechanical and electrical
10 mA
12 V
Galvanically isolated
Integrated into the instrument, the switch contact is actuated
in case of leakage in the reference chamber
Resistive load A
5
1)
1
0.75
0.5
0.25
5
1)
5
1)
12-pin TTI plug-in terminal
Min. 0.25 mm
Max. 2.5 mm
In cable socket
WIKA operating instructions, model GDM-RC-100-T
Inductive load A
3
1)
1
0.75
0.03
0.03
2
1)
2
1)
2
2

Werbung