6 Putting into operation

6.1 Connections
6.2 Carbon electrode
All manuals and user guides at all-guides.com
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to for the entire duration of
maintenance, servicing, mounting, dismounting and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Disconnect all electrical connections.
DANGER
Risk of injury and machine damage when handled by
unauthorised persons
Incorrect repair work and modifications to the product may lead to major
injuries and machine damage. The product warranty will be rendered
invalid if the unit is handled by unauthorised persons.
• Operating, maintenance, cleaning, fault and repair work may only be
carried out by qualified personnel (in Germany see TRBS 1203).
NOTICE
• Please take note of the following instructions:
 3.1 Technical data on page EN-4
NOTICE
• Use only water- and oil-free compressed air and observe the allowed
pressure of 7-10 bar at 600-1000 l/min.
To connect the gouging torch, proceed as follows:
 Fig. 1 Overview of the gouging torch on page EN-6
1 Keep the compressed air valve (8) on the handle (7) closed.
2 Slide the compressed air hose onto the compressed air nozzle (5) and
secure it with a hose clamp.
3 Fasten the welding current cable to the connection lug and tighten it.
 Fig. 1 Overview of the gouging torch on page EN-6
6 Putting into operation
EN - 7