Gouging torch

8 Putting out of operation

9 Maintenance and cleaning

All manuals and user guides at all-guides.com
WARNING
High sound level
The sound level of 105 to 118 dB is above the permissible limit value.
• Wear ear protection.
NOTICE
• The device may only be operated by qualified personnel (in Germany
see TRBS 1203).
• Clamping length of the carbon electrode to the plasma arc approx. 
150 mm.
• Please also consult the operating instructions for the welding
components, such as power source, compressed air line.
Before igniting the plasma arc, please observe the following:
1 Switch on the cutting current.
2 Open the compressed air valve.
3 Ignite the plasma arc by briefly touching the carbon electrode with the
workpiece and slide the carbon electrode back a little.
4 Keep the plasma arc length extremely small and pass the carbon electrode
evenly over the workpiece.
The compressed air jet usually follows this and air-blasts the melt.
NOTICE
• Please also consult the operating instructions for the welding
components, such as power source, compressed air line.
To put the gouging torch out of operation, proceed as follows:
1 Pull back the carbon electrode.
2 Close the compressed air valve.
3 Switch off the power source.
Regular cleaning, however, is a prerequisite for a long life and a trouble-free
operation.
8 Putting out of operation