4.5.2 External thermostat

The stove can also be controlled by an external thermostat if desired.
The external thermostat is connected to the main control unit at input "I03" & "GND".
The 2-pole plug required for this purpose is available from your Austroflamm dealer as an option under Art. No.
728 151.
The external thermostat must be connected by an authorised Austroflamm service engineer. Only potential-free
thermostats may be connected.
IMPORTANT: After installing the EXTERNAL THERMOSTAT, set the desired temperature and start the stove
manually to activate the "EXTERNAL THERMOSTAT" FUNCTION.
The external thermostat starts / stops your pellet stove 10 seconds after the desired room setpoint temperature
has been reached, or the temperature has fallen below this value.

Function diagram