Operating manual Clou Compact 2.0
9.2.4

Converting external air connection

Fig. 34: Removing the perforated cut-out
Fig. 35: Fastening the flexible aluminum
hose
EN
1) To remove the cover and the side cladding, Proceed
as described in the section Removing the side clad-
ding.
2) Using a saw, remove the perforated cut-out to the side
cladding (rear).
3) Fasten a flexible aluminum hose with a clamp to the
air supply connection.
4) Pull through the flexible aluminum hose at the rear
lower opening.
5) Remount side cladding and attach cover.
ð Air connection is converted at the rear.
9 | Installation