12 | Adjustments
12.3 Menu item - fuel
Fig. 64: Fuel
12.4 Menu item - eco-mode
Fig. 65: Eco-mode
12.5 Menu item - external thermostat
Fig. 66: External thermostat
48
EN
This submenu can be used to disable "filling level indic-
ator".
When deactivated the bar on the display disappears.
There will be no warning when the filling level is low.
Eco-mode enables the stove to be automatically turned off
and on at certain temperature settings specified by you.
You can set the switch-off and restart temperature in the
eco-mode menu item.
To prevent starting / stopping too frequently, the temperate
limits should not be set too narrowly. The stove must burn
for at least an hour in order to come to operating temperat-
ure.
As a standard setting we recommend a restart temperature
of 0.5 °C and a switch-off temperature of 1 °C.
The stove can optionally be controlled by an external ther-
mostat.
1) For this purpose connect the potential-free contact of
the thermostat to the main control at input "I03" &
"GND".
ð The 2-pin plug is optionally available (item no.
728151).
2) Then the function must be enabled in the menu Set-
tings/External thermostat.
ð The "External contact" display shows whether the
external thermostat is switched ON or OFF.
ð The stove will start/stop with a slight delay.
3) The external thermostat must be connected to the
controls at the slots "I03" & "GND" (DC series).
ð It applies the temperature control after enabling in
the "External thermostat" menu item.
TIP
To enable the external thermostat, the stove must be
manually started once after the thermostat has been in-
stalled.
Operating manual Scotty Duo