6 Replacing the internal controller battery

The control unit switches to internal battery power during a power failure or when disconnected from the mains
power supply. A STAND-BY BATTERY then supplies power to the internal clock and memory.
Please bear in mind: If the battery is flat, the control unit will function normally as long as it is connected to the
mains power supply. However, in the event of a power failure, the internal clock will stop and the operating
phase is not saved. When the power is restored, the clock is reset to 00:00 and the control unit leaves your
stove in the OFF phase.
Replacing the battery (recommendation: every 2 years):
1.
The battery is located on the central control unit. To access the control unit, open the inspection lid and
remove the right-hand cladding on the side of the stove.
2.
Then remove the black panel on the control unit by unscrewing 4 cross-head screws.
3.
Remove the old storage battery from the retainer.
4.
Insert the new battery, paying attention to the correct polarity.
5.
Screw the panel of the control unit back on.
6.
Refit the right-hand side cladding.
7.
Close the inspection lid and screw it firmly back into place.