Operating Indicators - IFM Electronic ecomot100 CR2511 Gerätehandbuch

Ausgangs-modul
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

value range
value output
free-wheel diode
is integrated!
Note

Operating indicators

OFF
ON
LED green
flashing
2 Hz
OFF
LED red
ON
If both faults occur simultaneously, the LED appears orange.
All manuals and user guides at all-guides.com
-2000 ... +2000 mA
> +2000 mA are rounded to +2000 mA
< -2000 mA are rounded to -2000 mA
values between -100...+100 mA are interpreted as "OFF"
100 ... 2000 mA are present at the odd-numbered
outputs (1, 3, 4, 7)
-2000 ... -100 mA are present at the even-numbered
outputs (2, 4, 6, 8)
To avoid a falsification of the measuring result, no external
free-wheel diode must be connected in parallel with the
load in operating mode „current-controlled output".
Digital and PWM/current output can be combined as a pair
(see also „Configuration examples", page 31)
CANopen state: PREOPERATIONAL / PREPARED
- NodeGuard error (if NodeGuarding is active)
- no synch objects (if synch monitoring is active)
no supply voltage
module in the stand-by mode
outputs = OFF
module active
CANopen state: OPERATIONAL
outputs are updated
communication o.k.
communication disturbed
CR2511
OUTPUT MODULE
PAGE
33