Object directory

Manufacturer Specific Profile Area; index 2000 to 5FFF

Index S-idx Designation
I/O
0
Configuration
Output
1
channel 1
Output
2
channel 2
Output
3
channel 3
Output
4
channel 4
2000
Output
5
channel 5
Output
6
channel 6
Output
7
channel 7
Output
8
channel 8
PWM
2001
0
Frequency
Explanation of the abbreviations:
0x... = hexadecimal number
str
= string
rw
= read-write
ro
= read only
u8
= unsigned 8 bit
u16 = unsigned 16 bit
u32 = unsigned 32 bit
(see also „Terms and abbreviations", page 48)
36
PAGE
All manuals and user guides at all-guides.com
Type
Default
u8, ro
0x08
u8, rw
0x02
u8, rw
0x02
u8, rw
0x02
u8, rw
0x02
u8, rw
0x02
u8, rw
0x02
u8, rw
0x02
u8, rw
0x02
0x64
u8, rw
(100 Hz)
Description
Number of the entries
(= number of the output channels)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
0 = OFF
2 = binary output
4 = analog output (PWM)
5 = analog output (current-controlled)
Setting in Hz
Range = 20 Hz to 250 Hz
Values below 20 Hz or above 250 Hz are not
accepted. The existing value remains valid.