Herunterladen Inhalt Inhalt Diese Seite drucken

Dimensions; Mounting; Electrical Connection - IFM Electronic ecomot100 CR2511 Gerätehandbuch

Ausgangs-modul
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Dimensions

Mounting

In order to expose the output module to the minimum mechanical stress it
should preferably be mounted horizontally or vertically on the mounting panel.
The module must be fixed with four screws to DIN 7500 or DIN 7984 (M5 x L).
If possible, the output module should be mounted in such a way that the cable
entry of the plug points downwards.
As the self-heating of the electronics of the unit is dissipated via the housing, suf-
ficient cooling must be ensured in case of "sandwich mounting" of modules.

Electrical connection

Designation
Operating voltage
Ground
Operating voltage outputs
CAN interface
To guarantee the electrical interference protection of the module,
the housing must be connected to GND.
(e.g. to the ground of the vehicle)
To protect the whole system (wiring and output module) the individual electric cir-
cuits must be protected with max. 16A.
All manuals and user guides at all-guides.com
43
5,5
LED
Pin No.
23
01
05
14 / 51
32 / 50
15 / 33
±1
132
15
±1
106,5
Potential
+VBB
S
GND
S
+VBB
O
CAN_H
CAN_L
CAN_GND
CR2511