8 Starting up

8.1 First-time operation

Unforeseen movements, falling workpiece carrier
Injury caused by falling objects.
Make sure that the product has been installed correctly by qualifi ed personnel
(see page 8) before starting it up.
Unforeseen movement, falling Liftgate
Injuries due to falling Liftgate.
Guide the Liftgate by the handles throughout the entire opening or closing
process.
Malfunctions due to incorrect installation and startup
The product can be damaged; the service life may be adversely affected.
Starting up requires basic mechanical, pneumatic and electrical knowledge.
The product may only be operated by qualifi ed personnel (see page 8).
• Before fi rst use or re-commissioning, check that the Liftgate is operating safely,
especially the force feedback that occurs during opening and closing.
• Before fi rst use or re-commissioning of a conveyor system, run a risk assessment in
accordance with DIN EN ISO 12100.
• According to EU Machinery Directive 2006/42/EC, you must equip the transfer
system with EMERGENCY STOP devices.
• The surfaces of engines and gearboxes can reach temperatures of over 65 °C under
certain load and operating conditions. In these cases, you must comply with the
appropriate design measures (protective measures) or the corresponding warnings
of the applicable accident prevention regulations (UVV)!
• Make sure that all electrical and pneumatic connections are in use or closed.
Check that all screws and plugs are securely fastened. All relevant protective covers
must be installed.
• Continuous conveyors which are in motion or in operation may only be inspected
and adjusted once all required safeguards are in place.
• Note EN ISO 13857 when you remove or replace safeguards and / or nullify a safety
guideline.
• Test runs with open panels are only allowed if they are carried out by a competent
person using tip switches and no interference through other switching elements
exists.
• Only start up the product when all safety devices of the system are installed and
are operational.
• Only start up a fully assembled product.
CAUTION
NOTICE
3 842 358 734/2015-01, MIT: Liftgate, Bosch Rexroth AG
Starting up
35/44

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis