12 /40 Bosch Rexroth AG | Electric Drives and Controls

5 Initial Operation

5
Initial Operation
Before initial operation, the proper seat of all
jumpers must be ensured. For initial operati-
on, please proceed as follows
1 Check whether a battery is correctly
seated in the battery holder. If not, insert a
battery according to the instructions in
section 4.1.
2 Insert SE302 into system box or BT300.
3 If applicable, insert the SMxxx interface
module in the SE302.
4 Those slots not occupied with interface
modules (X8, X9), must be closed off
using dummy panels (see section 5.4).
5 Turn on voltage supply for the system box
or card rack.
6 Connect operating computer.
7 Configure the interfaces and program the
tightening system.
5.1
Control elements
On the front plate of the tightening system
control SE302 two LEDs are installed to indi-
cate the operating condition:
LED
green
ready for operation
red flashing
system error
green flashing
Nutrunner in bypass
Nutrunner in sequence
test
Fig. 2:
5.2
This interface is intended for connecting a
programming device.
Fig. 3:
Pin Signal Description/
1
2
3
4
5
6
7
8
9
Table 3:
LED
green
Tightening
result OK
red flashing
Tightening
result NOK
SE302 | 3 609 929 819/1.1
Interface X 6: RS232
5
1
9
6
SUB-D-plug, 9pin
Function
-
RxD
RS232 Receive
TxD
RS232 Send
24 V
24 V Power
supply for SD301
GND
Reference
potential logic
-
RTS
RS232 Request
Send
CTS
RS232 Enable
Send
-
Voltage/Cur-
rent/Standard
–12 V...+12 V,
RS232
–12 V...+12 V,
RS232
24 V=, 300 mA
–12 V...+12 V,
RS232
–12 V...+12 V,
RS232