Trouble shooting

1
Fig. 9: LED
6 Trouble shooting
The MSA213C features diagnostic measures which are able to detect and
report to the drive control system any internal errors as well as errors that
occurred during mounting/installation.
Below are some typical errors which may occur during installation and
operation:
• Magnetic tape wrongly mounted, active side below (see chapter 4.2).
• The masking tape provided was not used for protecting the magnetic
tape. The masking tape must not be magnetizable.
• Magnetic sensor not or incorrectly connected (pin assignment see
chapter 4.4).
• The distance tolerances were not observed over the whole measuring
Fig.
8).
length (see
• Cable squeezed / interrupted / cut by sharp edges.
• The magnetic sensor has been mounted with the active side turned
away from the tape (see
• Magnetic sensor has not been aligned according to
• The magnetic sensor was taken into operation without magnetic tape.

7 Transport, Storage, Maintenance and Disposal

Transport and storage
Handle, transport and store the magnetic sensor with care. Pay attention
to the following points:
• Transport and / or store the magnetic sensor in the unopened origi-
nal packaging.
• Protect the magnetic sensor from harmful physical influences includ-
ing dust, heat and humidity.
• Do not damage connections through mechanical or thermal impact.
MSA213C · Date 19.04.2021 · Art. No. 89792 · Mod. status 340/18