Trouble shooting

Command
Length Reply
s
1/2
tx
2/2
ux
2/2
vklmnop
7/2
w
1/3
y
1/6
z
1/10
7 Trouble shooting
Below are some typical errors which may occur during installation and
operation:
• Magnetic tape wrongly mounted, active side below (see chapter 4.2).
• The masking tape provided was not used for protecting the magnetic
tape. The masking tape must not be magnetizable.
• Magnetic sensor not or incorrectly connected.
• The distance tolerances were not observed over the whole measuring
length or the sensor scrapes the magnetic tape (see
• Cable interrupted / squeezed / cut by sharp edges.
• The magnetic sensor has been mounted with the active side turned
away from the tape (see
• Magnetic sensor has not been aligned according to
• Magnetic fields near the measuring surface distort the measuring val-
ues. If required, pro-vide for adequate screening.
• Wrong measuring values due to EMC interferences (see chapter 4).
MSA510/1 · Date 04.05.2016 · Art. No. 83520 · Mod. status 38/16
Description
">"
Set device to original state; default values
(alignment is retained!):
counting direction: upward
code: Gray code
zero-point value: 0
resolution: 0.01 mm
">"
write counting direction (non-volatile)
x=0: upward
x=1: downward
"xy"
read out internal values (only for use in
our factory!)
">"
write baud rate (volatile) "klmnop":
004800, 009600, 019200, 038400, 057200
oder 115200
"xyz"
read out hexadecimal position value
"0x3b>"
read out flag register (for internal pur-
poses)
"+1234567>" read out ASCII position value
Fig.
6,
Fig.
7).
English
Fig.
7).
Fig.
6,
Fig.
7.