Commissioning

5 Commissioning
Following correct mounting and wiring you can put the measuring system
into operation by switching on operating voltage.

6 Trouble shooting

Below are some typical errors which may occur during installation and
operation:
• Magnetic tape wrongly mounted, active side below (see chapter 4.2).
• The masking tape provided was not used for protecting the magnetic
• Magnetic sensor not or incorrectly connected (pin assignment see
• The distance tolerances were not observed over the whole measuring
• Cable squeezed / interrupted / cut by sharp edges.
• The magnetic sensor has been mounted with the active side turned
• Magnetic sensor has not been aligned according to

7 Transport, Storage, Maintenance and Disposal

Transport and storage
Handle, transport and store the magnetic sensor with care. Pay attention
to the following points:
• Transport and / or store the magnetic sensor in the unopened origi-
• Protect the magnetic sensor from harmful physical influences includ-
• Do not damage connections through mechanical or thermal impact.
• Prior to installation inspect the magnetic sensor for transport dam-
Maintenance
With correct installation according to chapter
requires no maintenance. Clean the surface of the magnetic tape with soft
cloth from time to time if it is very dirty.
MSK400/1 · Date 07.02.2018 · Art. No. 81145 · Mod. status 44/18
tape. The masking tape must not be magnetizable.
chapter 4.4).
Fig.
6).
length (see
away from the band (see
nal packaging.
ing dust, heat and humidity.
ages. Do not install damaged magnetic sensors.
Fig.
6).
4
the magnetic sensor
English
Fig.
6.
23