22
Installation
WARNING
NOTICE
NOTICE

4.4 Electrical installation

Destruction of parts of equipment and loss of regulation control
` All lines for connecting the magnetic sensor must be shielded (not
with IO-Link).
` Never wire or disconnect electrical connections while they are live.
` Perform wiring work in the de-energized state only.
` Wiring to the screen and ground (0 V) must be secured to a good
point. Ensure that the connection of the screen and earth is made to a
large surface area with a sound connection to minimize impedance.
` Check all lines and plug connections before switching on the device.
` Switch on operating voltage together with the downstream electronic
unit (e. g., control unit).
Basically, all connections are protected against external interference.
Choose a place of operation that excludes inductive or capacitive inter-
ference influences on the magnetic sensor or its connection lines. When
mounting the system keep a maximum possible distance from lines loaded
with interference. If necessary, provide additional installations including
screening shields or metallized housings. Contactor coils must be linked
with spark suppression.
` Pay attention to the maximum length of the connection cable between
sensor and downstream electronics.
` Do not use tinned strands in connection with screw clamp connections.
Connection type
• E1: open cable end.
Interface without LD, 1Vss
Color
SSI
black
GND
brown
+UB
red
nc
yellow
nc
orange
nc
green
nc
blue
T+
violet
T-
gray
D+
white
D-
MSA213C · Date 19.04.2021 · Art. No. 89792 · Mod. status 340/18
BiSS C
GND
+UB
nc
nc
nc
nc
MA
NMA
SLO
NSLO
English