Specifications 1.25 kN ... 25 kN (for 200% calibration)
Nominal (rated) force
Spring element material
Measuring point protection
Cable (only with "integrated cable" option)
Cable length
Mechanical shock resistance as per IEC 60068‐2‐6
Number
Duration
Acceleration
Vibrational stress as per IEC 60068‐2‐27
Frequency range
Duration
Acceleration
Weight (with adapter)
Weight (without adapter)
1)
Test condition: 1 m water column, 100 hours
U10M/U10S
F
nom
m/s
m/s
m
m
A01385_06_YIC_06 HBM: public
kN
1.25
2.5
Aluminum
Measuring element
tightly sealed
Six-wire connection, TPE electrical in­
sulation. Outside diameter 5.4 mm
m
n
ms
2
Hz
min
2
kg
1.2
lbs
2.65
kg
0.5
lbs
1.1
Specifications
5
12.5
25
Stainless
steel
Hermetically
sealed mea­
suring ele­
ment
6 or 15
1000
3
1000
5 ... 65
30
150
3
6.61
1.3
2.87
43