Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting With A Fitted Force Application Part - HBM U10M Montageanleitung

Vorschau ausblenden Andere Handbücher für U10M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Nominal
(rated) force
torque M
1.25 - 5 kN
12.5 - 25 kN
50 - 125 kN
225 - 250 kN
450 - 500 kN
1.25 MN
1)
Lightly oiled bolts
M
Fig. 7.2
Installation without an adapter
Fit the bolts diagonally: after tightening one bolt, continue with the opposite
bolt. Do not apply the specified torque immediately, increase the tightening
torque in several steps. Initially, the bolts should only be hand-tight. Then
tighten them diagonally in several steps up to the specified torque.
7.6

Mounting with a fitted force application part

The U10M can also be ordered as an option with a fitted force application bolt.
The transducer can then measure axial forces in both the tensile and pressure
directions. If the sensor is loaded alternately with tensile and compressive
forces, the upper and lower threaded connectors with locknuts must be pre-
U10M/U10S
Tightening
1)
B
Num­
in N⋅m
ber
9
8
15
8
76
12
150
16
380
16
890
24
B
A01385_06_YIC_06 HBM: public
Bolts for transducer mounting
Metric
M6 x 40
M6 x 40
M10 x 1.25 x 55
M12 x 1.25 x 80
M16 x 1.5 x 100
M22 x 1.5 x 150
Mechanical installation
Property
UNF Grade
class
8.8
1/4"
10.9
1/4"
10.9
3/8"
12.9
1/2"
12.9
5/8"
12.9
7/8"
M
B
5
8
8
9
9
9
25

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

U10s

Inhaltsverzeichnis