Herunterladen Inhalt Inhalt Diese Seite drucken

HBM U10M Montageanleitung Seite 23

Vorschau ausblenden Andere Handbücher für U10M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Nominal (rated) force
in kN
1.25
2.5
5
12.5
25
2. Pre-stressing with tensile forces
Force transducers with any nominal (rated) force can be mounted using this
method. The procedure should always be used for force transducers from
50 kN in dynamic sustained loading, as the torque moment required for the
locknut would be too high in Method 1.
S Screw the force application part into the transducer or adapter as far as the
retainer.
S Unscrew force application part two revolutions.
S Load the force transducer in the tensile direction to 120% of the maximum
operating force. The following table shows the tensile forces to be applied
when the transducer is subsequently loaded with the nominal (rated) force.
Correspondingly smaller tensile forces can be used for applications in small
force ranges.
Nominal (rated) force
50 kN
125 kN
225 kN
250 kN
450 kN
500 kN
1.25 MN
The pre-stressing forces increase correspondingly when transducers with
the option "200% calibration" are used. If, for example, a U10M/125KN is
U10M/U10S
Tightening torque M
in N@m
in lb@inch
17
35
68
135
135
A01385_06_YIC_06 HBM: public
Mechanical installation
A
in mm
150
26.4
310
26.4
600
26.4
1195
26.4
1195
26.4
Tensile force to be applied
60 kN
150 kN
270 kN
300 kN
540 kN
600 kN
1.5 MN
Thread reach
in inch
1.04
1.04
1.04
1.04
1.04
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

U10s