Number of
measuring bridges
Rated output
Calibration
Transducer
identification
Mechanical design
Plug protection
Electrical
connection Bridge A
U10M/U10S
For reasons of redundancy, in devices relevant to safety it is
necessary to check the plausibility of the measurement signal
with a second measuring bridge (installed on the same mea­
suring element). The signals are independently conditioned
and evaluated using two separate measuring amplifiers.
The exact rated output (nominal) is specified on the type
plate. The transducer can also be adjusted to an exact rated
output of 1.0 mV/V or 2.0 mV/V (if 200% calibration selected:
2 mV/V or 4 mV/V). The rel. rated output error is then 0.1% of
the rated output (nominal). The rated output range of a unad­
justed transducer lies between 1 and 1.5 or 2 and 2.5 mV/V.
The sensors can be connected in parallel if this option has
been chosen.
(Exception: Transducers with nominal (rated) force 1.25 MN
cannot be connected in parallel)
In the standard version, the transducer is designed for use
with alternating loads of up to +/- 100% of Fnom. For applica­
tions with a limited oscillation bandwidth (tensile force or com­
pressive force measurement only) or static or quasi-static
forces, the transducer can be loaded with double its nominal
(rated) force. Calibration at 200% of F
this.
TEDS integration (integrated electronic data sheet) in accor­
dance with IEEE1451.4
Optionally, you can also use the U10 as a flange. This version
does not include the screwed foot adapter. During mounting,
please observe the notes in these instructions.
Mechanical protection through the installation of an additional
square profile around the connector.
Dimensions in mm approx.: WxHxB: 30x30x20
The standard version is the device plug with bayonet locking
(PT02E10-6P-compatible). The option is also available to pro­
vide a screw-fitting device plug (PC02E10-6P-compatible). A
third variant where the force transducers are fitted with a fixed
cable is also available. In this version, all U10 achieve degree
of protection IP68 with a nominal (rated) force equal to or
greater than 12.5 kN.