Specifications 1.25 kN ... 25 kN (for 100% calibration)
Nominal (rated) force
General information
Degree of protection as per EN 60529, with bayonet
connector (standard version), socket connected to
sensor
Degree of protection as per EN 60529, with "threaded
connector" option
Degree of protection as per EN 60529, with
"integrated cable" option
Spring element material
Measuring point protection
Cable (only with "integrated cable" option)
Cable length
Mechanical shock resistance as per IEC 60068‐2‐6
Number
Duration
Acceleration
Vibrational stress as per IEC 60068‐2‐27
Frequency range
Duration
Acceleration
Weight (with adapter)
Weight (without adapter)
1)
Test condition: 1 m water column, 100 hours
U10M/U10S
F
kN
nom
m
n
ms
m/s
Hz
min
m/s
kg
m
lbs
kg
m
lbs
A01385_06_YIC_06 HBM: public
1.25
2.5
IP67
Aluminum
Measuring element
tightly sealed
Six-wire connection, TPE electrical in­
sulation. Outside diameter 5.4 mm
2
2
1.2
2.65
0.5
1.1
Specifications
5
12.5
25
IP67
IP64
1
IP68
)
Stainless
steel
Hermetically
sealed
measuring
element
6 or 15
1000
3
1000
5 ... 65
30
150
3
6.61
1.3
2.87
37