2. An isolating device must be connected to the power supply cable.
Isolating device (disconnecting means) should have minimum
3.0 mm contact gap.
Connect the approved polychloroprene sheathed power
supply 1 cord and power supply 2 cord and type designation
60245 IEC 57 or heavier cord to the terminal board, and to
the other end of the cord to isolating device (Disconnecting
means). See below table for cable size requirement.
Power
Model
Supply
Indoor Unit
Outdoor Unit
Cord
WH-
WH-UD03JE5*,
SDC0305J3E5
WH-UD05JE5*
WH-
WH-UD07JE5*,
SDC0709J3E5
WH-UD09JE5*
3. To avoid the cable and cord being damaged by sharp edges, the
cable and cord must be passed through a bushing (located at
the bottom of Control Board) before terminal board. The bushing
must be used and must not be removed.
Terminals on the Outdoor Unit
Colour of wires (Connecting cables)
Terminals on the Indoor Unit
L
(Power Supply Cord)
Terminals on the isolating
L
devices from power supply
(Disconnecting means)
Power Supply 1
RCCB/ELCB
*1
Holder
(Clamper)
Power Supply Cord
Terminal screw
Tightening torque cN•m {kgf•cm}
M4
M5
*1 - Earth wire must be longer than other cables for safety reasons
WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
No loose strand
(gap between wires)
when insert
Conductor
Conductor
fully insert
over insert
ACCEPT
PROHIBITED
Isolating
Recommended
Cable Size
Devices
RCD
2
1
3 x min 1.5 mm
15/16A 30mA, 2P, type A
2
3 x min 1.5 mm
2
15/16A 30mA, 2P, type AC
1
3 x min 2.5 mm
2
25A
30mA, 2P, type A
2
3 x min 1.5 mm
2
15/16A 30mA, 2P, type AC
1
2
N
L
N
1
2
1
1
Indoor Unit/
N
L
N
1
1
Outdoor Unit
connection
Power Supply 2
Terminal Board
*1
Connecting Cable
157~196 {16~20}
196~245 {20~25}
Indoor/outdoor
connecting
terminal board
5mm or more
Conductor not
fully insert
PROHIBITED
CONNECTING REQUIREMENT
For Indoor Unit with WH-UD03JE5*, WH-UD05JE5*, WH-UD07JE5*,
WH-UD09JE5*
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3
and can be connected to current supply network.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-11
and shall be connected to suitable supply network, with the following
maximum permissible system impedance Z
the interface. Please liaise with supply authority to ensure that the
Power Supply 2 is connected only to a supply of that impedance
or less.
INSTALLATION OF REMOTE
6
CONTROLLER AS ROOM
THERMOSTAT
3
Remote Controller 3 mounted to the Indoor Unit can be moved to
the room and serve as Room Thermostat.
3
Installation Location
Install at the height of 1 to 1.5 m from the fl oor (Location where
average room temperature can be detected).
Install vertically against the wall.
Avoid the following locations for installation.
1. By the window, etc. exposed to direct sunlight or direct air.
2. In the shadow or backside of objects deviated from the room
airfl ow.
3. Location where condensation occurs (The Remote Controller
is not moisture proof or drip proof.)
4. Location near heat source.
5. Uneven surface.
Keep distance of 1 m or more from the TV, radio and PC. (Cause
of fuzzy image or noise)
Remote Controller Wiring
Indoor Unit
Terminal for Remote Controller wiring
Remote Controller cable shall be (2 x min 0.3 mm²), of double
insulation PVC-sheathed or rubber sheathed cable. Total cable
length shall be 50 m or less.
Be careful not to connect cables to other terminals of Indoor Unit
(e.g. power source wiring terminal). Malfunction may occur.
Do not bundle together with the power source wiring or store in the
same metal tube. Operation error may occur.
= 0.352 ohm () at
max
Remote Controller
Remote Controller wiring
(fi eld supply)
No polarity
1
2
9