Tank
32. MonFloor operation time (max)
Set max operating hours of heating.
When max operation time is shortened, it can boil the tank more frequently.
It is a function for Heating + Tank operation.
33. Tank heat up time (max)
Set max boiling hours of tank.
When max boiling hours are shortened, it immediately returns to Heating
operation, but it may not fully boil the tank.
34. Tank re-heat temp.
Set temp to perform reboil of tank water.
(When boiled by heat pump only, (51°C – Tank re-heat temp) shall become
max temp.)
Setting range is -12°C ~ -2°C
35. Sterilization
Initial setting: 65°C 10min
Set timer to perform sterilization.
1 Set operating day & time. (Weekly timer format)
2 Sterilization temp (55~75°C  If use back-up heater, it is 65°C)
3 Operation time (Time to run sterilization when it reached setting temp
5min ~ 60min)
User shall set whether to use or not to use sterilization mode.
3-5. Service Setup
36. Pump maximum speed
Normally setting is not necessary.
Please adjust when need to reduce the pump sound etc.
Besides that, it has Air Purge function.
When *Pump fl ow setting is Max. Duty, this duty set is the fi x pump duty run
during room side operation.
37. Pump down
Operate pump down operation
Initial setting: 8h
Initial setting: 60min
Initial setting: -8°C
Initial setting: Depend on model
Service setup
Pump down:
ON
Confi rm
30min ~ 10h
①  ③
Service setup
Flow rate
88:8 L/min
Select
12:00am,Mon
Service setup
Pump down:
Heat
Tank
Heat
Tank
5min ~ 4h
-12°C ~ -2°C
12:00am,Mon
Max. Duty
Operation
Air Purge
0xCE
12:00am,Mon
Pump down operati o n i n progress!
ON
OFF
Confi rm