MAINTENANCE
SCHEDULE
Monthly
CAUTION
• When working, the high pressure cleaner should not be too noisy and there should be no obvious drips
of water or oil underneath it. If this is the case have the machine checked by a Specialized Technician.
Special maintenance must only be done by a Specialized Technician, complying with the following table.
MAINTENANCE
SCHEDULE
Every 200 hours
Every 400 hours
• Every 200 hours, carry out alternately the maintenance intervals indicated in the table.
CAUTION
• The data given in the table are approximate. It might be necessary to carry out maintenance more
frequently in the case of particularly heavy work.
PROBLEMS
When the switch (1) is
moved to "1" position,
LED (31) does not turn on
• Clean the water inlet filter (35 or 14): refer to what has been explained previously.
• Clean the detergent suction filter  (29).
It is normally enough to put the filter under running water or blow it with compressed
air to clean it. In the most difficult cases use a scale remover or replace it, contacting
an authorised assistance centre to buy the new filter.
• Clean the nozzle.
It is normally enough to put the pin (24) supplied through the hole of the nozzle to
clean it. If the results are not good, replace the nozzle purchasing it from an authorised
assistance centre.
The nozzle can be replaced using a 14 mm box spanner (not supplied).
• Check soundness of the water inlet and outlet circuits.
• Check tyre inflation pressure.
• Check clamping of the pump to the engine and the engine to the frame.
If clamping is found to be insecure do not, under any circumstances, use the
high pressure cleaner and contact a Specialized Technician.

SPECIAL MAINTENANCE

• Check the pump's hydraulic circuit.
• Change pump oil.
• Check the pump suction/delivery valves.
• Check tightness of pump screws.
TROUBLESHOOTING
CAUSES
The switch to which the power
cable plug is connected is in "0"
position.
Tripping of system cutout device
to which the high pressure cleaner
is connected (fuse, RCCB, etc.).
The plug is not properly fitted.
JOB
JOB
• Check pump clamping.
• Check the pump regulation valve.
• Check the safety devices.
REMEDIES
Move the master switch to "1" position.
Reset the cutout device.
IN CASE THIS TRIPS AGAIN, DO NOT USE
THE HIGH PRESSURE CLEANER AND
CONTACT A SPECIALIZED TECHNICIAN.
Disconnect the plug and fit it back correctly.
(continues on the next page)