PROBLEMS
The high pressure cleaner
stops during operation.
Having released the spray
gun lever (15) and after
about 13 seconds, the
Total Stop function fails
to activate.
When the master switch
(1) is turned, the motor
hums but does not start.
Orange indicator light
(32) on
The high pressure washer
stops and does not start
again, the indicator lights
(31) and (32) are flashing.
CAUSES
Tripping of system cutout device
to which the high pressure cleaner
is connected (fuse, RCCB, etc.).
Tripping of thermal protection or
ampere cut-out protection.
W o r k
p r e s s u r e
30 bar/435 psi: the device does not
activate under such conditions.
Remember not to leave the high
pressure cleaner in by-pass for
more than 3 minutes.
Electrical system and/or extension
and/or power cable (Xtreme) are
inadequate.
Maintenance needed.
Micro-leaks were clearly detected
in the delivery circuit which
caused the high pressure washer
to restart several times: a special
device stopped the high pressure
washer.
Reset the cutout device.
IN CASE THIS TRIPS AGAIN, DO NOT USE
THE HIGH PRESSURE CLEANER AND
CONTACT A SPECIALIZED TECHNICIAN.
Follow the instructions of the "Safety
devices" paragraph.
b e l o w
None.
Make sure the power line connection
instructions have been followed (see the
Instruction manual – Safety precautions),
and check the instructions in the "Installation"
paragraph.
- Carry out maintenance
(see section Special Maintenance)
Turn the main switch (1) to position "0", wait
a few seconds and restart the high pressure
washer.
IF IT TRIGGERS AGAIN, DO NOT USE THE HIGH
PRESSURE WASHER AND CONTACT A SKILLED
TECHNICIAN.
REMEDIES
EN
35