Herunterladen Inhalt Inhalt Diese Seite drucken

RayTek MI3 Betriebsanleitung Seite 118

Miniatur infrarot sensor
Vorschau ausblenden Andere Handbücher für MI3:
Inhaltsverzeichnis

Werbung

ASCII Programmierung
Description
Char
Output 1 source
O1O
(O)
Output 2 source
O2O
Output 3 source
O3O
2
Output 4 source
O4O
3
Peak hold time
P
4
Power / AD value
Q
Presel. Setpoint
SV
Target temperature
T
Get Analog Input 1
TV1I
Get Analog Input 2
TV2I
Temperature Unit
U
Poll / Burst mode
V
Command counter
W
Burst string contents
X$
Multidrop Address
XA
Profibus / Modbus
XAS
Address
Device Bottom range
XB
limit
Restore Box Factory
XF
defaults
Transmission
XG
Device High range limit XH
for MI3COMM only
1
for MI3MCOMMA only
2
for MI3MCOMMA only
3
setting average / peak / valley / advanced hold cancels all other hold modes
4
118
Format
P B S N Legal Values
O1O=v,
or nT,
1
or nI
O2O=v,
or nT,
or nI
O3O=v,
or nT,
or nI
O4O=v,
or nT,
or nI
nP
√ √ √ √ 0.0 - 998.9s
float
?nQ
nSV
float
?nT
√ √
float
?TV1I
?TV2I
X
√ √ √ √ C / F
V=P
?W
√ √
?X$
0nn
n
?nXB
float
float
√ √ √
?nXH
float
Rev. F2 03/2014
v – float value
n – head number
if v = 60 – controlled by
head 1(O1O=1T)
v – float value
n – head number
if v = 60 – controlled by
head 1(O2O=1I)
v – float value
n – head number
if v = 60 – controlled
by head 1 (O3O=1I)
v – float value
n – head number
if v = 60 – controlled
by head 1(O4O=1I)
(999 = ∞)
answer !nT=0099.9
0 – 5V
0 – 5V
P=poll B=burst
1 – 0x7FFF (repeat)
Set to 1 when V=P
√ √ 000 – 032
(000 --> single unit mode)
√ √ 0 – 125 (Profibus)
1 – 247(Modbus)
answer !nXB=10.0
0.1 – 1.0
read only
Factory default Head /
Box
O1O=1I
B
O2O=1T
B
O3O=1I
O4O=1I
0.0s
H
H
500°C
H
H
B
B
C
B/H
poll mode
B
1
B
B
000
B
0 (Profibus)
B
1(Modbus)
H
except address B
1.0
H
H
MI3