Herunterladen Inhalt Inhalt Diese Seite drucken

RayTek MI3 Betriebsanleitung Seite 116

Miniatur infrarot sensor
Vorschau ausblenden Andere Handbücher für MI3:
Inhaltsverzeichnis

Werbung

ASCII Programmierung
Description
Char
External module
EM
Presel. Emissivity
EP
Pointer
Emissivity Source
ES
Presel. Emissivity Value EV
Valley hold time
F
1
Flicker Filter
FF
Average time
G
2
Head Address
HA
Connected heads
HC
Registered heads
HCR
Head Status Code
HEC
Head identification
HI
Top temperature value
H1O
of output 1
(H)
Parameter error
Register write error
Analog module error
Profinet ready
setting average / peak / valley / advanced hold cancels all other hold modes
1
setting average / peak / valley / advanced hold cancels all other hold modes
2
Head Status Codes (read only):
3
Temperature unit
Object temperature out of range
Ambient temperature out of range
Parameter error for a command
Register write error
Self-test error
Head not connected
Ambient temperature compensation
Head access error
Object temperature out of range
Ambient temperature out of range
Temperature is over setpoint
Self factory default executed
for MI3COMM only
4
116
Format
P B S N Legal Values
?EM
nEP
integer
nES
integer
nEV
float
nF
√ √ √ √ 0.0 - 998.9 s
float
nFF
integer
nG
√ √ √ √ 0 – 999.0 s
float
nHA
string
string
nHEC
16 bit hex
?nHI
string
float
4
BIT3
BIT4
BIT5
BIT6
BIT0 // 0 = °C, 1 = °F
BIT1 // 1 = out of range
BIT2 // 1 = out of range
BIT3 // 1 = error
BIT4 // 1 = error
BIT5 // 1 = error
BIT6
(ab Rev. 2.20, not for Profibus communication boxes)
BIT7 // 0 = off, 1 = on
BIT8
(ab Rev. 2.20, not for Profibus communication boxes)
BIT9
(ab Rev. 2.20, not for Profibus communication boxes)
BIT10
(ab Rev. 2.20, not for Profibus communication boxes)
BIT11
(ab Rev. 2.20, not for Profibus communication boxes)
BIT12
(ab Rev. 2.20, not for Profibus communication boxes)
Rev. F2 03/2014
0 – no module
2 – 2 channels
4 – 4 channels
(analog outputs)
0 - 7
I = Emissivity from Internal
(by command)
E = Emissivity from
External analog input
(0V - 5V)
D = digital selected FTC1-3
0.1 - 1.1
(999 = ∞)
0...32768
1 – 9
e.g. !HC – no heads
!HC1 2 3 7 8
e.g. !HCR – no heads
!HCR1 2 3 7 8
HCR=0 –> new registration
hex value of Status Code
e.g. !7HIMIXLTS22
(√
)
√ √ H1O= –40.0
or H= –40.0
Factory default Head /
Box
B
0
H
I
H
H
0.0 s
H
0 (LT, G5)
H
3000 (1M, 2M)
0.0 s
H
B
B
B
H
3
set at production H
500°C
B
MI3

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Verwandte Produkte für RayTek MI3

Inhaltsverzeichnis