Condensate drain
Compressors (Fig. 14)
Draining the condensate from the pressure vessel is
recommended during regular operation. Switch off the
compressor at the mains. Reduce air pressure in the
device to max. 1 bar by releasing air via a connected
device. Install the hose from the basic package into the
drain valve. Put the vessel under the hose and release the
condensate from the tank by opening the release valve (1).
Carefully and slowly open the drain valve. Quickly opening the drain valve is
accompanied by a loud sound and uncontrollable stream of accumulated condensate.
Compressors without a dryer may be equipped with the
Automatic Condensate Drain to allow the condensate to
drain without operator intervention (see chap. 8.2.).
Compressors with air dryer (Fig. 15)
Condensate
from
automatically drained into a condensate collection vessel.
The vessel must be drained regularly.
Monitor the level in the vessel using the 1 l or 2 l markings (depending on the
volume of the vessel), and empty at least once a day. The vessel may overflow if
the condensate is not drained out of the vessel at the defined interval.
Risk of slipping on a wet floor in case of the condensatecollection vessel
overflow.
THE FOLLOWING IS REQUIRED BEFORE ANY FOLLOW-UP CHECKS
Compressors with cabinet - release the door lock and open the cabinet door.
Safety valve check
(Fig. 16)
When the compressor is operated for the first time, make
sure that the safety valve is working properly. Turn the screw
(2) on the safety valve (1) several rotations to the left until
the safety valve releases air. Let the safety valve vent for
only a few seconds. Turn the screw (2) to the right until it
seats, closing the valve.
Never use the safety valve to vent air pressure in the air tank. It could damage the
safety valve. The valve is set to the maximum permitted pressure by the
manufacturer. Adjustments are not permitted!
WARNING! COMPRESSED AIR IS DANGEROUS BECAUSE OF THE RISK OF
DAMAGE TO THE EYES! RISK OF DAMAGE TO THE EYES.