Troubleshooting
A. Leakage with MultiFaster connected.
A1. Locate the leaking line.
A2. Disconnect the MultiFaster.
A3. Replace the damaged seal of the leaking male coupling.
A4. Connect the MultiFaster and increase the pressure in the specific
line.
A5. In case leakage continues, replace the female coupling too.
A6. If leakage continues again, verify that the lever is not deformed.
This could cause a misallignement of the MultiFaster and the seals
could be damage during connection.
B. Leakage after connection under pressure.
B1. Proced as descibed in steps A1, A2, A3 and A4.
B2. In case leakage continues, replace both the female coupling and
the male coupling of the specific line.
B3. If leakage continues again, proceed as described in step A6.
C. Leakage from disconnected mobile part.
C1. Locate the leaking line.
C2. Proceed as described in steps A3 and A4.
C3. In case the leakage continues, replace the male coupling of the
specific line.
C4. If the leakage continues again, replace the female coupling and the
steal of the male coupling.
C5. If the leakage goes on, proceed as described in step A6.
D. Leakage from disconnected fixed part.
D1. Locate the leaking line.
D2. Replace the female coupling of the specific line.