Air Cleaner Service
Replace the paper element at the intervals indicated in
the service schedule. See Section 5.1.2 for the service
schedule.
See Figure 5-8 for the air cleaner
components.
1. Loosen the two cover retaining knobs and remove
the cover.
2. Remove the paper element.
3. Do not wash the paper element or use pressurized
air, as this will damage the element. Replace a
dirty, bent, or damaged element. Handle new
elements carefully; do not use if the sealing
surfaces are bent or damaged.
4. When servicing the air cleaner, check the air
cleaner base. Make sure it is secured and not bent
or damaged. Also, check the element cover for
damage or improper fit. Replace all damaged air
cleaner components.
Note: If any loose dirt or debris fell on the air cleaner
base when the element was removed, carefully
remove it and wipe the base clean. Be careful
that none of it drops into the intake throat.
5. Reinstall the paper element onto the air cleaner
base. Make sure the element is flat and properly
seated.
6. Install the air cleaner cover and secure with the two
retaining knobs.
7. When element replacement is necessary, order
genuine Kohler parts.

5.5 Cooling System

The engine fan draws cooling air through the openings
in the sides and end near the battery. The alternator fan
draws cooling air through openings on the side walls of
the enclosure. The cooling air mixes with the engine
exhaust and is discharged at the exhaust outlet. See
the service view in Section 1.8 for air intake and exhaust
locations. To prevent generator set damage caused by
overheating, keep the housing cooling inlets and outlets
clean and unobstructed at all times.
Note: Do not block the generator set cooling air inlets or
mount other equipment above them. Overheating
and severe generator damage may occur.
TP-6804 1/15

5.6 Exhaust System

WARNING
Carbon monoxide.
Can
cause
fainting, or death.
The
exhaust
leakproof and routinely inspected.
Remove all combustible materials from the exhaust
location. Combustible materials include building
materials as well as natural surroundings. Keep dry
field grass, foliage, and combustible landscaping
material a minimum of 1.2 m (4 ft.) from the exhaust
outlet.
Periodically inspect the exhaust system components for
cracks, leaks, and corrosion.
Check for corroded or broken metal parts and replace
D
them as needed.
Check that the exhaust outlet is clear.
D

5.7 Fuel Regulator Vent Tubes

If the generator is equipped with the fuel regulator vent
tubes shown in Figure 5-9, check that the tubes are not
blocked. Clean out the tubes, if necessary.
1. Regulator vent tubes, qty. 2
2. Check for debris. Clean out the tubes, if necessary.
Figure 5-9 Fuel Regulator Vent Tubes (if equipped)