Injection unit not activated
(max. stroke movement)
Stroke movement injection unit
Fig. 12
NOTE
• Observe the max. stroke movement for injection.
• The max. stroke travel (traverse movement of the welding torch) should not exceed 6 mm.
• We recommend a maximum injection impulse of 3 s.
• Use the adjusting screw (8) to adjust the amount of anti-adhesives per injection impulse (see Fig.
• The residual oil of the anti-spatter from the injection unit is collected in the drain bottle (7) (see Fig.
You can activate the device manually via the cover in order to set the dosing of the anti-adhesives.
• When setting the anti-spatter adjustment manually, wear safety goggles.
• An injection pulse is activated by lightly pressing down the cover.
• You can assess the amount of the atomized anti-spatter by the produced spray mist.
• The injection pulse should only be activated for max. 2 sec.
• You can increase or reduce the amount of anti-spatter via the adjusting screw (8) (see Fig. 11 Adjusting
the anti-spatter fluid on page EN-16).
NOTE
• A small amount of anti-spatter is sufficient to achieve the desired effect.
The injection pulse is reset when moving out of the injection unit.
11 Adjusting the anti-spatter fluid on page EN-16).
11 Adjusting the anti-spatter fluid on page EN-16) and can be reused after cleaning particulate from
it.
CAUTION
Injection unit
activated
6 Putting into operation
EN - 17