Herunterladen Inhalt Inhalt Diese Seite drucken

caprari K+ Serie Betriebs- Und Wartungsanleitung Seite 23

Elektrischen abwasser - tauchmotorpumpen
Vorschau ausblenden Andere Handbücher für K+ Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 67
8.9 Operation with inverter/converter: the use of this electronic equipment as control and regulation unit, must be studied very carefully
in order to verify that it doesn't produce electromagnetic interferences or induced currents which can reduce the safety standard
required by the ATEX norms in reference to the zone in which the equipments are working.
In any case, the following conditions must be respected:
- it is compulsory to use the inverter Danfoss VLT FC202 (ex VLT8000) serie or more recent models with better performances;
use of models corresponding to other brands must be authorized by Caprari S.p.A.;
- it is compulsory to set the inner commutation frequency of the inverter at maximum 4kHz or at the minimum frequency admitted
by the inverter;
- it is compulsory to equip the inverter with the correct battery of filters, between inverter and the motor, for the reduction
of [dv/dt];
- it is compulsory to use the inverter only in the modulation range 35 - 60 Hz.
8.10 The standard maximum ambient temperature is 40°C. A maximum ambient temperature of 60°C can be accepted on request and
following tests by Caprari S.p.A. This temperature will be indicated on the rating plate of the electric pump.
marking:
dNV
Legend:
CE mark shows the conformity to the 94/9/CE directive (usually named ATEX);
specific symbol for the explosion-proof protection;
II
equipment group declaration (non-mining);
2
equipment category declaration; (EPL);
G
risk typology (G=gas);
Ex d
protection scheme (d = flame-proof enclosures);
II
apparatus group declaration (non-mining);
B
joints and gaps typology (gases range);
T4
classification according to maximum surface temperature (T4 = 135°C max);
Gb
explosive atmosphere containing gas, vapours or mists + category of equipment (EPL);
TÜV IT19ATEX 027AR
the electric pump technical dossier (according to Enclosure VIII) submitted to the Notified Body TÜV IT0948;
BUREAU VERITAS 1370 identification number of the Notified Body for verifications during the production phase;
TÜV IT19ATEX 020X
the motor conformity at the type (Enclosure III) is realized by TÜV IT0948;
Dangerous zone
Gases, vapours or mists
Gases, vapours or mists
Gases, vapours or mists
caprari S.p.a.
K.M150N.. / K.M100N.. / K.W100N.. / K.d200N.. / K.M200P.. / K.d250P..
II 2G Ex d IIB T4 Gb - tech.file TÜV IT19ATEX 027AR (electric pump)
II 2G Ex d IIB T4 Gb - TÜV IT19ATEX 020X (motor)
Category according to 94/9/CE Directive
zone 0
Zone 1
Zone 2
1G
2G oppure 1G
3G, 2G oppure 1G
GB
EPL (IEc 60079-0)
Ga
Gb, Ga
Gc, Gb, Ga
23

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis