3. System Description

The components of the CleanSpace HALO system are shown in Section 7. The respirator draws ambient air through
the high efficiency filter and supplies filtered air to the wearer via the mask. CleanSpace HALO is a breath
responsive respirator which means that it blows harder during inhalation and more softly during exhalation. The
device continuously adjusts fan speed to maintain positive pressure in the mask. Should the filter become blocked,
an audible alarm will sound and the "Filter" light on the keypad will be illuminated. If the battery voltage falls below
the minimum required to sustain the designed flow rate, an audible alarm will sound.
Properly selected, used and maintained respirators help to protect against certain airborne
contaminants. It is essential to follow all instructions and government regulations on the use of this
product, including wearing the complete respirator system during all times of exposure, in order for
the product to help protect the wearer. Misuse of respirators may result in overexposure to
contaminants and lead to sickness or death. For proper use, see your Occupational Health

4. List of Warnings within these User Instructions

This product is part of a system that helps protect against certain airborne contaminants. Misuse may result in sickness or death. For proper use, see your
Occupational Health Specialist, these user instructions or contact CleanSpace Customer Service on sales@cleanspacetechnology.com or visit our
Properly selected, used and maintained respirators help to protect against certain airborne contaminants by reducing concentrations in the wearer's breathing
zone. It is essential to follow all instructions and government regulations on the use of this product, including wearing the complete respirator system during all
times of exposure, in order for the product to help protect the wearer. Misuse of respirators may result in overexposure to contaminants and lead to sickness
or death. For proper use, see your Occupational Health Specialist, these user instructions or contact CleanSpace Customer Service on
CleanSpace HALO is a tight fitting respirator and National standards recommend the user be clean shaven.
IF A SATISFACTORY FIT FACTOR CANNOT BE ACHIEVED WITH ANY OF THE MASKS, CLEANSPACE HALO MUST NOT BE USED
Misuse of CleanSpace Respirators by cleaning the filter may result in overexposure to contaminants and lead to sickness or death.
IF A SATISFACTORY FIT CANNOT BE ACHIEVED, DO NOT ENTER THE CONTAMINATED ZONE
Be sure to remove the Seal Check Cap before entering the contaminated area. The Cap blocks the exhalation valve, making it more difficult for your
exhaled air to be expelled from the mask. Failure to remove the cap will lead to build-up of Carbon Dioxide in the mask, and may result in headache or
DO NOT REMOVE THE RESPIRATOR UNTIL YOU HAVE VACATED THE CONTAMINATED AREA unless you have immediate and sudden onset health
reasons to do so (for instance you are experiencing dizziness and believe removing the respirator while you leave the contaminated area may help)
IT IS ESSENTIAL THAT THE CORRECT FILTER TYPE IS SELECTED FOR THE CHOSEN APPLICATION.
If the blocked filter alarm is triggered (2 beeps, repeated every second, red LED flashes), leave the contaminated area immediately and replace the filter.
Operating the respirator after the blocked filter alarm has sounded can cause the flow to fall below the manufacturer's minimum designed flow, which
DO NOT USE WATER, COMPRESSED AIR OR ANY OTHER MECHANICAL METHOD TO CLEAN THE FILTER!
FILTERS ARE EASILY DAMAGED BY THE USE OF WATER, COMPRESSED AIR OR BY BRUSHING.
Misuse of CleanSpace Respirators by cleaning the filter may result in overexposure to contaminants and lead to sickness or death.
Use only NIOSH or CE Mark-approved CleanSpace
filters other than CleanSpace. Use of other filters may result in overexposure to contaminants and lead to sickness or death.
CleanSpace HALO is not intrinsically safe. Do not use in flammable or explosive atmospheres. Doing so may result in injury or death.
Specialist, these user instructions or contact CleanSpace Customer Service
sales@cleanspacetechnology.com or visit our website:www.cleanspacehealth.com
sales@cleanspacetechnology.com or visit our website:www.cleanspacehealth.com
DO NOT USE COMPRESSED AIR OR A BRUSH TO CLEAN THE FILTER!
FILTERS ARE DAMAGED BY THE USE OF COMPRESSED AIR OR BY BRUSHING.
dizziness. Never leave the Cap in place for more than 2 minutes!
may result in overexposure to contaminants and lead to sickness or death.