6. Electrical connection

Only by a specialist!
Please observe:
VDE 0100
EN
The installation must comply with current IEC and national local regulations or any particular
regulations, specified by the local electricity supply company
The rating plate and technical specifications
The appliance must be earthed!

Wiring diagram

(fig. E1)
1. Electronic circuitry
2. Heating element
3. Safety pressure cut-out
4. Terminal strip
5. Safety thermal cut-out

Structural prerequisites

The appliance must be installed via a permanent connection. Heater must be earthed!
The electric wiring should not be injured. After mounting, the wiring must not be direct
accessible.
An all-pole disconnecting device (e.g. via fuses) with a contact opening width of at least
3 mm per pole should be provided at the installation end.
To protect the appliance, a fuse element with trigger characteristic C must be fitted with a
tripping current commensurate with the nominal current of the appliance.

7. Initial operation

Vent the device according to the enclosed image manual.
After every draining (e.g. after work on the plumbing system or following
repairs to the appliance), the heater must be re-vented in this way before
starting it up again.
If the water heater cannot be put into operation, the temperature cut-out or the pressure cut-out
may have tripped during transport. If necessary, check that the power supply is switched off and
reset the cut-out (fig. F1 + F2).

Selection of power rating

Only by authorised specialist, otherwise lapse of guarantee!
Upon first connection of the appliance to the supply voltage, select the maximum power rating.
Only after having set the power rating, the heater provides its standard operation mode.
The maximum allowable power rating at installation site depends on the local situation. It is
imperative to observe all data shown in the table "Technical specifications", in particular the
required cable size and fuse protection for the electrical connection. Moreover, the electrical
installation must comply with the statutory regulations of the respective country and those of the
local electricity supply company (Germany: DIN VDE 0100).
1. Switch on the power supply to the appliance.
2. When switching on the supply voltage for the first time, the touch screen shows the menu to
select the language after about 40 seconds. Choose your language, after that the selection
of power rating appears. If not, please follow the note "Reinstallation".
3. Select the maximum allowable power rating depending on the local situation via touch (18,
21, 24 or 27 kW).
4. Press "OK" to confirm the setting.
5. Mark the set power rating on the rating plate.
6. After having set the maximum allowable power rating, the heating element will be activated
after approx. 10 – 30 sec of continuous water flow.
7. Open the hot water tap. Check the function of the appliance.
8. Remove the battery case cover of the remote control and insert batteries (2 × AAA Alkaline).
Mind the polarity of the batteries. Insertion should take place when the power supply of the
water heater is turned on and the remote control is near the appliance. The display indicates
all symbols for about 4 seconds after inserting the batteries, after that the remote control is
connected to the instantaneous water heater.
Electrical connection from below
Note: If necessary, the connecting terminal can be displaced to the upper part of the appliance.
To do this, please follow the instructions in the operating and installation manual available online.
Check that the power supply is switched off prior to electrical connection!
1. Dismantle approximately 6 cm off the connecting cable above the wall outlet (fig. E2). With
the smaller opening ahead, slide the water splash protection sleeve over the connecting
cable so that the sleeve is flush with the wall. This prevents any leaking water from coming
into contact with the electrical leads. It must not become damaged! The protection sleeve
must be used!
2. Open the control panel rightwards.
3. Strip the cables and plug them in the connecting terminals according to the wiring diagram.
The appliance must be earthed.
4. Pull the protective sleeve over the connecting cables until the sleeve fits perfectly in the
recess of the intermediate panel. Adjust the water splash protection sleeve as illustrated and
fix it with the sleeve fixing (A). Reinsert the control panel and lock it on (fig. E3).
5. Place the hood on the appliance and screw in the fastening screw. After that you can slide
on the faceplate from the bottom up to the stop.
Note: Load shedding and electrical connection from above
For further informations please use the online operation and installation
instruction. Please follow the link below or use the QR code via smart-
phone or tablet.
https://www.clage.de/links/gma/DSX-Touch-GMA-9120-34385
9. Explain the user how the instan ta neous water heater works and hand over the operating
instructions to the user.
10. Fill in the guarantee registration card and send it to the CLAGE After-Sales Service or use
the online regis tration on our website (see also page 10).

Reinstallation

In case the appliance will be commis sioned again under different installation conditions than
during its initial ope ration, it may be necessary to adapt the maximum power rating.
A temporary short-circuit of the two pins on the right, e.g. with a screwdriver acc. to EN 60900
(see figure F3), will reset all heater parameters to works setting and lock the heating. The touch
screen shows the menu to select the language. Choose your language, after that the selection
of power rating appears. This condition will maintain when activating and deactivating the supply
voltage.

Shower application

The water heater's temperature must be limited to 55 °C, if it is connected to a shower. The tem-
perature limit must be set to a value less or equal 55 °C in the setting menu, in consultation with
the customer and the lock level must be activated.
When the appliance is operated with preheated water, it must be ensured that this temperature
is limited to 55 °C as well.

Notes in case of remote control connection problems

In case of a failing connection between the remote control and the water heater, the display
indicates "bt". A keystroke restarts the registration.
Under those circumstances reduce the distance to the water heater and check whether the
power supply is turned on.